Low Speed Vehicle Battery 60V20Ah
Low Speed Vehicle Battery 60V20Ah
Provides power to low speed vehicles like 2/3 wheelers. Designed to be "Deep-cycle" that means the battery system can be discharged until almost empty, voltage nominal 60V and energy is 1.28kWh.
-
Safe & Endurable
Self-developed BMS provides the ultmost protection to battery, compatible with major Inverter brands.
-
Smart BMS
The battery detection unit is installed in the battery pack, which can accurately and real-time detect the battery voltage, temperature, capacity and other conditions, which can fully improve the safety of the product.
-
10 Years Design Life
A-class battery cells, with the protection of BMS, the system can deliver up to 10 years servicelife.
-
Reliable
Longer lifespan Laser Welding Rigid tests before shipment.
-
Adaptable
Self-heating function, consistent and efficient at -20 to 50 degrees.
-
Intelligent Monitoring
Monitor the battery status at any time on the APP, while the LCD window displays real-time data, battery charging, discharge and other data at a glance.
-
LiFePO4
A+ Tier Cells
-
64V
Voltage
-
1.28kWh
Energy
-
≥3500
Battery Cycles
-
5years
Warranty
| 60V20Ah- EV Battery- Low Speed Vehicles | |||
| SPECIFICATIONS | |||
| Rated Capacity | 20Ah | ||
| Rated Energy | 1.28kWh | ||
| Nominal Voltage | 64V | ||
| Dimension | 280*170*140mm | ||
| Weight | approx. 11kg | ||
| Charge Cut-off Voltage | 73V | ||
| Discharge Cut-off Voltage | 50V | ||
| Rated Charge Current | 10A | ||
| Rated Discharge Current | 30A | ||
| Rated Discharge Current in 30S | 50A | ||
| Communication | CAN/RS485 | ||
| Port of Charge & Discharge | Same Port | ||
| Protection Level | IP65 | ||
| Working Temperature | Charge: 0~45℃ | ||
| Discharge: -20~60℃ | |||
| Storage Temperature | 10~45℃ | ||
| State of Charge(SOC) before Shipment | 30%~50% | ||
| PROTECTION PARAMETERS | |||
| Single Cell Over Charge | Protection Voltage | 3.68V | Can be set manually |
| Restore Voltage | 3.60V | Can be set manually | |
| Protection Delay | 5.0s | Can be set manually | |
| Restore Conditions |
1.Auto restore once the voltage drops to the value. 2.Detecting there is a valid discharging current from battery. |
||
| Single Cell Over Discharge | Protection Voltage | 2.5V | Can be set manually |
| Restore Voltage | 2.9V | Can be set manually | |
| Protection Delay | 5.0s | Can be set manually | |
| Restore Conditions |
1.Auto restore once the voltage rises to the value. 2.Detecting there is a valid charging current from battery. |
||
| Total Voltage Over Charge | Protection Voltage | 73V | Can be set manually |
| Restore Voltage | 70V | Can be set manually | |
| Protection Delay | 5.0s | Can be set manually | |
| Restore Conditions |
1.Auto restore once the total voltage drops to the value. 2.Detecting there is a valid discharging current from battery. |
||
| Total Voltage Over Discharge | Protection Voltage | 50V | Can be set manually |
| Restore Voltage | 58V | Can be set manually | |
| Protection Delay | 5.0s | Can be set manually | |
| Restore Conditions |
1.Auto restore once the voltage rises to the value. 2.Detecting there is a valid charging current from battery. |
||
| Charge Over Current | Protection Current | 22A | Can be set manually |
| Protection Delay | 5.0s | Can be set manually | |
| Restore Conditions |
1.Auto restore and re-detect every 2minutes, stops after 10times repetition. 2.Detecting there is a valid discharge current. |
||
| Discharge Over Current | Protection Current | 48A | Can be set manually |
| Protection Delay | 15s | Can be set manually | |
| Restore Conditions |
1.Auto restore and re-detect every 2minutes, stops after 10times repetition. 2.Detecting there is a valid charge current. |
||
| Temperature | Top Charge Temperature | 65℃ | Can be set manually |
| Lowest Charge Temperature | 0℃ | Can be set manually | |
| Top Discharge Temperature | 65℃ | Can be set manually | |
| Lowest Discharge Temperature | -10℃ | Can be set manually | |